Posted in

How to test an elevator relay?

If you’ve ever waited for an elevator that hesitated, jerked mid-move, or failed to respond to a call button press, chances are small but critical part is to blame: the elevator relay. As someone who’s spent 12 years sourcing, testing, and supplying these relays to elevator maintenance teams, small contractors, and major elevator OEMs, I can tell you this isn’t just a component—it’s the “nervous system” that turns button presses into smooth rides and doors that open and close on cue. Elevator Relay

Too often, though, people test relays wrong, wasting hours chasing phantom issues or missing a failing relay that could lead to a service call or worse. That’s why today I’m walking through exactly how I train our clients to test elevator relays—tests I’ve refined over thousands of shipments and on-site troubleshooting visits. No fancy lab equipment needed, just basic tools and a step-by-step process that works every time.

First, let’s get clear on what we’re testing here. Elevator relays aren’t the tiny relays you swap in a car’s radio—they’re heavy-duty, industrial-grade parts built to handle constant, high-load cycling (sometimes 10,000 times a day in a high-rise office). Their jobs range simple: triggering door open/close solenoids, switching the elevator’s direction from up to down, and activating the brake that holds the car in place when it stops. Fail here, and you’re not just stuck—you’re looking at costly downtime.

Prep: Safety First, Tools Second

Before you touch a single wire, this is non-negotiable: Elevators run on 120V, 240V, even 480V AC power, depending on the setup. If you’re working on an active elevator trip the main power breaker for that elevator and post a lockout-tagout sign so no one flips it while you’re working. I still remember a new tech I trained skipping this step and getting a shock that took him out for a week—don’t be that person.

Once power is locked out, grab three basic tools:

  1. A multimeter (digital is fine, no need for a $500 Fluke unless you do this every day) that works for AC voltage, DC voltage, and continuity.
  2. A clean, dry cloth and a small screwdriver (flathead, mostly, to avoid stripping the terminal screws).
  3. The relay’s original datasheet—every reliable elevator relay supplier includes this, and it has the exact coil voltage, contact rating, and pinout for your model. If you don’t have yours, reach out to who you buy from (that’s us, if you’re shopping) for a free copy—we send them within 24 hours for every relay we ship.

Step 1: Visual Inspection (The 2-Minute Check That Catches 30% of Failures)

Before you even use the multimeter, start with a hands-on look. This is the fastest way to spot obvious damage that would ruin a test. Pull the relay out of its socket (most elevator relays are plug-and-play, no soldering required) and go over every inch:

  • Look for discoloration on the plastic casing: Tan, brown, or black spots mean the relay overheated at some point—either from overloaded contacts or a coil that drew too much current. We see this all the time when relays get mismatched to a high-load door operator.
  • Check the metal contact prongs on the bottom for bending, pitting, or corrosion. If they’re bent, they won’t seat right in the socket, leading to intermittent connections. If they’re pitted or corroded, that’s a sign arcing happened—an early warning of contact failure.
  • Listen for a loose rattling inside the plastic. Gently tap the relay against your palm. A working relay should feel solid, no loose parts. Rattling usually means the internal armature is worn or the coil has shifted—another sign the relay is nearing end of life.

Pro tip: If the relay is new, skip the rattling check (it’s sealed at the factory) and just look for any packaging damage— we’ve had a handful of shipments where a box got crushed, nicking the casing of a relay inside. Better to catch that before installation.

Step 2: Coil Test (Make Sure the Relay Can Turn On)

The relay’s coil is the part that draws power to trigger the internal switch—if the coil is bad, the relay won’t activate at all. This is the most common hidden failure, and it’s super easy to test.

First, reference your datasheet to find the two coil pins. For example, our standard 24V AC elevator relay has pins 3 and 5 as the coil. Set your multimeter to the DC (or AC, whatever matches your coil voltage) resistance setting. Touch the two leads of your multimeter to the two coil pins. A working coil should have a resistance reading right around what’s listed on the datasheet—for our 24V coil, that’s about 150 ohms. If the reading is way higher (open loop, OL on the multimeter), the coil is broken. If it’s zero ohms, the coil is shorted out. Either way, that relay is done.

Important note: Don’t skip this for new relays! We’ve had a small batch from a factory run where the coil wire wasn’t connected properly, so a visual check looked perfect but the coil wouldn’t work. This test catches that before you install a dud.

Step 3: Contact Test (Make Sure the Switch Works)

Once you know the coil is good, it’s time to test the contacts—this is what actually switches the elevator’s power, so this test tells you if the relay will do its job. Relays have two types of contacts: normally open (NO, which is open until the coil is triggered) and normally closed (NC, which is closed until the coil is triggered). Most elevator relays use both, but focus on the ones tied to critical functions: door motors, direction control, and brake activation.

First, do the “off state” test with power still locked out. Set your multimeter to continuity mode (it beeps when two points are connected). For each set of contacts, touch your leads to the two contact pins. For NO contacts, it should not beep—they’re open when the relay is off. For NC contacts, it should beep—they’re closed when the relay is off. If this is reversed, the contacts are fused shut or worn out.

Next, test the “on state”—this is where you simulate the relay activating, since you can’t power the full elevator circuit (lockout is still in place!). You’ll need a 9V or 12V DC power supply (most common for relay testing) matched to your coil voltage, or even a fresh 9V battery. Touch the positive lead of your power supply to one coil pin, and the negative lead to the other—this triggers the relay, just like it would in the elevator.

Now, go back to your contacts and test continuity again. For NO contacts, they should now beep (closed when triggered). For NC contacts, they should not beep (open when triggered). If they don’t switch, the armature inside the relay is stuck, or the contact points are too worn to make a connection.

Real-world example: Last month, a client in Chicago called us panicking because 10 of their relays were causing elevator door jams. He’d tested the coils, which were fine, but skipped testing the contact switching. The relays’ contacts had a thin layer of oxidation that only closed when a little extra pressure was applied—they worked when triggered by his 9V battery, but wouldn’t seat right when connected to the door operator’s 120V circuit. Once we sent him a set of our premium gold-plated contact relays (standard for high-cycle door applications), the jams stopped. That’s why this step matters—visible pitting or a failed continuity swap isn’t always obvious until you simulate real use.

Step 4: Load Test (Stress the Relay Like It Would in the Elevator)

Visual, coil, and contact tests are great, but they don’t account for the heavy load relays handle every day. A relay might pass a continuity test with a 12V battery, but fail when it’s switching 10A for a door motor. That’s why we always recommend a load test, especially for relays that control high-power functions.

You’ll need a load that matches your relay’s contact rating—say, a 10A 120V AC light bulb or a small heater (something that draws a steady, known load). Set up your test circuit: Lock out elevator power, remove the relay, and wire your load to the NO contacts’ line and load pins. Then, use your power supply to trigger the relay, just like before. The load should turn on smoothly, no flickering or dropping out. Watch the relay for 10 full seconds—if it’s overheating (you’ll feel it getting hot on the casing), or the load flickers, that’s a sign the contacts can’t handle the real load they’ll see in the elevator.

We built a custom test rig in our warehouse specifically for this, cycling relays on and off 10,000 times to simulate 6 months of use—we reject any relay that fails the load test during that cycling. That’s why our relays have a 5-year warranty, no fine print. Most small suppliers don’t do this level of testing, which is why you’ll see their relays fail after a year in high-rise elevators.

When to Replace vs. Reuse

Sometimes a relay passes all these tests, but is old—elevator relays have a typical lifespan of 100,000 cycles, which is about 10 years for a high-rise. If a relay is over that mark, even if it tests good, I’d recommend replacing it as a preventive measure. We always include free cycle counter stickers with every relay we ship, so our clients can track usage without needing a fancy tool.

The Big Mistakes I See All the Time

Over the 12 years in this business, I’ve seen maintenance techs skip steps that lead to callbacks. Let’s call these out so you avoid them:

  1. Forgetting lockout-tagout: As I mentioned earlier, this isn’t optional. I’ve had a client almost burn his shop down when he tested a relay without locking out power, and a wire shorted. Take 30 extra seconds to lock the breaker—worth it.
  2. Using the wrong multimeter setting: A lot of people mix up AC and DC voltage for coil tests, and get a wrong reading. Double-check your datasheet, and test the multimeter on a known good battery first to make sure it’s working.
  3. Ignoring arcing signs: If you see tiny sparks when you trigger a relay’s contacts, that’s arcing, and it’s wearing down the contacts faster. Even if it passes a basic contact test, that relay is going to fail soon—replace it.

Ready to Get the Right Relay, Tested to Last?

At the end of the day, testing a relay isn’t rocket science—but it is specific to elevators. Generic relays from big box stores won’t stand up to the daily cycle, so testing them is a waste of time. The best step is to source a relay supplier that provides specs, offers datasheets, and stands behind their parts. We don’t cut corners on testing, and every relay we ship is pre-qualified before it leaves our warehouse—saving you the hassle of doing all these tests yourself.

If you’re dealing with faulty elevator relays, need to restock for a big project, or just have questions about testing, reach out to our team. We’ll send you a free test guide tailored to your elevator model, and help you pick the right relay for your load requirements. No hard sell, just honest advice from a team that’s been in this industry long enough to know what works.

Other Elevator Pcb References

  1. Elevator Relay Testing Standards, National Elevator Industry, Inc.
  2. Industrial Relay Selection and Testing Guide, Electronics Weekly, 2022
  3. Lockout-Tagout Procedures for Elevator Maintenance, OSHA, 2021

Sanjin Elevator Parts Co., Ltd.
Sanjin Elevator Parts Co., Ltd. is one of the most professional elevator relay manufacturers and suppliers in China, featured by quality products and good service. Please rest assured to buy or wholesale high-grade elevator relay at competitive price from our factory.
Address: 18th Floor, Xinyuan Center, Fenghe Road, Xi’an, Shaanxi, China
E-mail: elevatorparts@westdt.com
WebSite: https://www.sanjinelevator.com/