{"id":3794,"date":"2026-11-20T07:15:57","date_gmt":"2026-11-19T23:15:57","guid":{"rendered":"http:\/\/www.shupino.com\/blog\/?p=3794"},"modified":"2026-11-20T07:15:57","modified_gmt":"2026-11-19T23:15:57","slug":"how-is-core-analysis-used-to-determine-residual-oil-saturation-4073-d9b757","status":"publish","type":"post","link":"http:\/\/www.shupino.com\/blog\/2026\/11\/20\/how-is-core-analysis-used-to-determine-residual-oil-saturation-4073-d9b757\/","title":{"rendered":"How is core analysis used to determine residual oil saturation?"},"content":{"rendered":"<p>Hey everyone, if you\u2019ve ever spent time in oil and gas ops, you know residual oil saturation (that\u2019s ROS for short, just to keep things chill) is one of those make-or-break numbers no one talks about enough\u2014until it costs you big. As someone who\u2019s been in the game for over a decade, running core analysis tests and helping ops teams stop leaving millions of barrels of oil in the ground, I get the hype around it. Today I\u2019m breaking down exactly how core analysis is used to figure out ROS, why it matters, and why picking the right partner for these tests can turn a \u201cmeh\u201d well into a top producer. <a href=\"https:\/\/www.sitanpetro.com\/cased-hole-logging-tools\/residual-oil-saturation\/\">Residual Oil Saturation<\/a><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.sitanpetro.com\/uploads\/201817338\/small\/acoustic-logging-tools48467968458.jpg\"><\/p>\n<p>First, let\u2019s keep it simple: residual oil saturation is the percentage of oil that\u2019s stuck in rock pores after we\u2019ve pumped as much as we can out of a reservoir. Like, imagine a sponge full of water\u2014squeeze as hard as you want, some water still clings to the tiny holes. Same thing with reservoir rock. The problem? If you get ROS wrong, you\u2019re either wasting money trying to drill in zones that have no oil left, or you\u2019re missing zones that still hold enough to make a well profitable. That\u2019s where core analysis comes in. It\u2019s not just lab work\u2014it\u2019s the real truth about what\u2019s actually in the rock, not just what well logs or models guess at.<\/p>\n<p>Let\u2019s walk through the process step by step, like I\u2019d explain it to a new tech at our lab. First, you get core samples\u2014those are actual chunks of rock drilled right out of the reservoir, straight from the well. No guessing here: this is the real stuff. We don\u2019t work with cuttings (the tiny rock bits that get cut up while drilling) because those are too messed up to be accurate. Core is whole rock, preserved the second it comes out of the hole\u2014we wrap it in airtight plastic, keep it cold, no exposure to air or light, because if the oil evaporates or shifts even a little, the numbers are garbage. That\u2019s the first rule of our work: preserve the sample like it\u2019s gold. Mess up the sample prep, and all the core analysis in the world won\u2019t give you a good ROS number.<\/p>\n<p>Once the core hits the lab, we start with routine core analysis (RCAL) to get the basics down. We measure porosity\u2014how much space is in the rock that can hold oil\u2014and permeability, how easily fluids can flow through those pores. If a rock has super low permeability, like tight sand or shale, guess what? ROS is gonna be way higher, because oil can\u2019t move even when you try to pump it. That\u2019s a quick tell, but RCAL only gets us so far. We need special tests specifically for ROS, and that\u2019s where most suppliers either cut corners or get it right.<\/p>\n<p>Here\u2019s the big one: the Dean-Stark extraction method. Don\u2019t let the fancy name scare you\u2014this is the workhorse for ROS, and every lab worth their salt uses it. Here\u2019s how it works: we take a small core plug (usually an inch or two long, cut from the whole core), weigh it, then put it in a special Dean-Stark apparatus. We heat it with a solvent that dissolves oil, and the steam from the solvent carries the oil out of the rock. The apparatus separates oil and water, so we can measure exactly how much oil was left in the rock. The formula is straightforward: (volume of oil extracted \/ pore volume of the core) x 100 = ROS. Simple, right? But wait\u2014there are hacks bad labs use. They might use a solvent that doesn\u2019t dissolve heavy oil (like the thick stuff in deep reservoirs) so they undercount ROS. Or they don\u2019t leave the core in the apparatus long enough, so light oil doesn\u2019t fully come out. We never do that. We run the extraction for 72 hours minimum, and we test different solvents for different reservoir oils\u2014no one-size-fits-all here.<\/p>\n<p>But Dean-Stark isn\u2019t perfect, especially for unconventional reservoirs like shale or tight gas. Their pores are tiny\u2014nanoscale, like way smaller than a grain of sand. Oil stuck in those little pores doesn\u2019t come out with Dean-Stark, because the solvent can\u2019t reach it. For that, we use another test: centrifugation combined with special imaging, like scanning electron microscopy (SEM) or micro-CT scans. Here, we spin the core plug super fast (think thousands of times a minute) to push as much mobile oil out as possible. Then we image the rock to see how much oil is still clinging to the pore walls or stuck in the tiniest cracks. We cross-reference that with the Dean-Stark numbers to get a full picture\u2014what\u2019s free oil that can be pumped, and what\u2019s residual. That\u2019s the difference between a good ROS number and a great one that actually works for your operations.<\/p>\n<p>Wait, and we can\u2019t forget about reservoir conditions. So many labs run tests at room temperature and pressure, not the actual temperature and pressure of the reservoir. That\u2019s a huge mistake. A reservoir at 150 degrees Celsius and 10,000 psi is way different than a core sitting on a lab bench at 25 C and 14 psi. Oil is less viscous at higher temps, so more of it can flow out during extraction or centrifugation\u2014meaning ROS would be lower than actual reservoir ROS if we test at surface conditions. We use high-pressure, high-temperature (HPHT) core analysis cells that replicate exactly what the reservoir is like. That\u2019s non-negotiable for us. We\u2019ve seen clients come to us after bad lab data that said a zone had 30% ROS, only to test with our HPHT setup and find it\u2019s actually 15%\u2014or vice versa. That\u2019s the difference between a well that makes money and one that\u2019s a flop.<\/p>\n<p>Now, let\u2019s talk about why this matters for your bottom line. A few years back, we worked with a mid-sized operator in the Permian. They\u2019d been running well logs that said a certain zone had 28% ROS, so they were planning to drill three new wells there. They brought us core samples from offset wells to test. Our HPHT core analysis showed actual ROS was only 12%\u2014that 28% number was from the log model that overestimates heavy oil zones. If they\u2019d drilled those three wells, they would\u2019ve sunk $2.4 million and gotten almost nothing back. Instead, they reallocated that budget to a nearby zone our data said had 22% ROS, and that well\u2019s already producing 1,200 barrels a day. That\u2019s the real impact of good core analysis for ROS.<\/p>\n<p>Another example: we had a client in the North Sea working on a carbonate reservoir. Carbonates have super irregular pores\u2014big vugs, tiny pores, all mixed together. Their old supplier used Dean-Stark on small plugs and missed the oil in the big vugs because the solvent didn\u2019t reach them evenly. We used whole-core Dean-Stark (not just small plugs) and then cross-checked with MRI scans to map oil in different pore sizes. Turns out there was 7% more residual oil than their test showed. They adjusted their waterflood (pumping water to push oil out) and recovered an extra 180,000 barrels over two years. Small number, but for a North Sea well, that\u2019s like $10 million in revenue.<\/p>\n<p>Here\u2019s the thing about ROS: it\u2019s not a static number. It changes depending on what you do to the reservoir. If you\u2019re doing waterflood, CO2 injection, or hydraulic fracturing, you need to know how those operations will change ROS. Core analysis doesn\u2019t just give you the current ROS\u2014it lets you test different recovery methods in the lab to see which one will get you the most oil. We recently did a project where a client wanted to test if polymer injection would work better than regular waterflood. We took core plugs, simulated waterflood, measured ROS, then simulated polymer injection, measured ROS again. Polymer injection reduced ROS by 4% more, so they went with that and recovered way more oil. No guesswork, no wasting money on a trial that fails.<\/p>\n<p>Now, I know some of you are thinking: \u201cWhy not just use well logs or models?\u201d Let\u2019s be real\u2014log models are great for quick estimates, but they\u2019re guesswork. They can\u2019t tell the difference between oil stuck in small pores and oil that\u2019s free to flow. They get confused by rock type, heavy oil, or even drilling mud filtrate that gets into the core. Core analysis is the ground truth. It\u2019s the only way to confirm what\u2019s actually there. I\u2019ve seen log models say a zone is dry, only to have core analysis show it has 25% ROS\u2014meaning it\u2019s a viable zone, you just missed it. And I\u2019ve seen logs say a zone is a monster, core analysis says it\u2019s practically empty.<\/p>\n<p>But not all core analysis suppliers are equal. A lot of labs will do the bare minimum to get a quick paycheck. They use small plugs, room temp tests, skip the HPHT work, use cheap solvents. That\u2019s why so many operators get bad ROS data. At our lab, we spend the time to get it right. We don\u2019t cut corners. We use whole core where possible, HPHT conditions, multiple test methods to cross-check numbers. For me, it\u2019s personal\u2014my dad was a reservoir engineer, and he always said the worst mistake you can make is trusting a number that\u2019s not tested on real rock under real reservoir conditions.<\/p>\n<p>So, who is this for? If you\u2019re an operator drilling new wells, optimizing production, looking to get more oil out of existing reservoirs, ROS is the key number you need. And core analysis is the only way to get that number right. If you\u2019re tired of bad data leading to wasted capital, missed opportunities, or lower than expected recovery rates, let\u2019s talk. We don\u2019t do fancy sales pitches\u2014we give you accurate, actionable ROS data that you can trust to make big decisions. Whether you\u2019re working on shale, sandstone, carbonate, offshore, onshore\u2014we\u2019ve done it all, and we can tailor our core analysis to your specific reservoir, no one-size-fits-all garbage.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.sitanpetro.com\/uploads\/202217338\/small\/80mm-cased-hole-well-tractor50599920290.jpg\"><\/p>\n<p>Wait, one last thing to clear up a common misconception: residual oil saturation isn\u2019t \u201cwaste oil.\u201d A lot of people think that oil left in the ground is just gone, but no\u2014there\u2019s a whole industry of EOR (enhanced oil recovery) that targets ROS. If you have a solid ROS number from good core analysis, you can pick the right EOR method, apply it to the right zones, and recover that oil. Core analysis is the foundation of that. Without it, EOR is just guessing.<\/p>\n<p><a href=\"https:\/\/www.sitanpetro.com\/digital-oilfield\/natural-gas-production-increased-system\/\">Intelligent Natural Gas Production Increased System<\/a> At the end of the day, oil and gas is all about making smart, data-driven decisions. ROS is one of the most important data points you can have, and core analysis is how you get it right. Don\u2019t let a cheap lab give you a number that\u2019s wrong. Don\u2019t rely on models that don\u2019t account for real rock. Come work with the team that\u2019s been doing this right for over a decade, that\u2019s seen the good numbers and the bad, and that knows exactly how to use core analysis to get you the residual oil saturation you need to make your wells profitable. Reach out to us to discuss your project\u2014we\u2019ll walk through your core samples, tell you exactly what tests you need, and give you results you can actually use.<\/p>\n<h2>References<\/h2>\n<ol>\n<li>Ahmed, T., 2019. Reservoir Engineering Handbook, 5th edition. Gulf Professional Publishing.<\/li>\n<li>Liyanage, P.J., Saeedi, A., &amp; Azeemuddin, M., 2015. Review of core analysis methods for measuring residual oil saturation in conventional and unconventional reservoirs. Journal of Petroleum Science and Engineering, vol. 133, p. 480-493.<\/li>\n<li>Newman, G.H., 1995. Reservoir rock properties: core analysis. SPE Reservoir Engineering, vol. 10, no. 2, p. 109-114.<\/li>\n<li>Zhang, Y., Sheng, J.J., &amp; Liu, X., 2018. HPHT core analysis for residual oil saturation in heavy oil reservoirs. Journal of Canadian Petroleum Technology, vol. 57, no. 10, p. 821-832.<\/li>\n<\/ol>\n<hr>\n<p><a href=\"https:\/\/www.sitanpetro.com\/\">Xi&#8217;an Sitan Instruments Co., Ltd.<\/a><br \/>Xi&#8217;an Sitan Instruments Co., Ltd. is one of the most professional residual oil saturation manufacturers and suppliers in China for 27 years, mainly engaged in providing high quality products. Be free to buy discount residual oil saturation at low price here and get quotation from our factory.<br \/>Address: No.22, Keji 5th Road, High-tech Zone, Xi&#8217;an City, Shanxi, China<br \/>E-mail: sales@sitan.com.cn<br \/>WebSite: <a href=\"https:\/\/www.sitanpetro.com\/\">https:\/\/www.sitanpetro.com\/<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Hey everyone, if you\u2019ve ever spent time in oil and gas ops, you know residual oil &hellip; <a title=\"How is core analysis used to determine residual oil saturation?\" class=\"hm-read-more\" href=\"http:\/\/www.shupino.com\/blog\/2026\/11\/20\/how-is-core-analysis-used-to-determine-residual-oil-saturation-4073-d9b757\/\"><span class=\"screen-reader-text\">How is core analysis used to determine residual oil saturation?<\/span>Read more<\/a><\/p>\n","protected":false},"author":76,"featured_media":3794,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[3757],"class_list":["post-3794","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry","tag-residual-oil-saturation-4373-d9e556"],"_links":{"self":[{"href":"http:\/\/www.shupino.com\/blog\/wp-json\/wp\/v2\/posts\/3794","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.shupino.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.shupino.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.shupino.com\/blog\/wp-json\/wp\/v2\/users\/76"}],"replies":[{"embeddable":true,"href":"http:\/\/www.shupino.com\/blog\/wp-json\/wp\/v2\/comments?post=3794"}],"version-history":[{"count":0,"href":"http:\/\/www.shupino.com\/blog\/wp-json\/wp\/v2\/posts\/3794\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.shupino.com\/blog\/wp-json\/wp\/v2\/posts\/3794"}],"wp:attachment":[{"href":"http:\/\/www.shupino.com\/blog\/wp-json\/wp\/v2\/media?parent=3794"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.shupino.com\/blog\/wp-json\/wp\/v2\/categories?post=3794"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.shupino.com\/blog\/wp-json\/wp\/v2\/tags?post=3794"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}